S-1 S-2 Regarding Parking Garage - The Building Code Forum Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy Because the Business Occupancy is a hazard to the S-2 occupancy, a fire barrier wall must be constructed between the two
Garage distance separation from dwelling - Section R309 Re: Garage distance separation from dwelling - Section R309 Uncle Bob, That's how I see it (I just don't believe it) I would not interpret measuring from overhang Any other comments on that? I'll probably stay 5' back The area where the two structure meet is only about 30" of wall length, but there is a window in the garage in that 30"
HVAC in a garage - The Building Code Forum Codes do not permit duct openings in a residential attached garage, for obvious reasons I ran across one yesterday where it appears that the contractor is placing an air handler in a garage under living space My first reaction is -not permitted- however as I thought about it I figured the
Step from garage into House?? - The Building Code Forum I do not see anywhere in the IRC 2015 that requires a step from the garage into the house I saw the opening penetrations R302 5 Garage section R309 Is the step still a requirement and if so is there a minimum dimension?
2024 Portal Frames - The Building Code Forum In the picture provided, I would say that is still a single portal frame opening I think the intent was to prevent two portal frames immediately adjacent to each other using a common header Example would be at the garage, where for example, multiple garage door openings are on the same wall plane and configured to use a common header over 2+ portal frames - that would be prohibited
Exit Access Stair in Open Parking Garage - Exit Discharge Typically an exit access stair is locate inboard with the exit travel distance continuing beyond the stair to the exit door, but not in this case due to the open parking garage exception
Clothes Dryer | The Building Code Forum All, is there a code section that requires a gas clothes dryer be elevated 18 inches above garage floor? I am sure this has been asked before but I cant recall, of all things, I have a retired inspector asking me this question and wanting an answer and explanation Thanks for your replies
Ribbon board or ledger board- room inside of balloon framed garage Building a garage for someone and decided to do the plans myself as an exercise I'm thinking of how to detail the framing on this bathroom (5x8) inside of the garage Particularly attaching the ceiling joists to the balloon framed wall; I checked the book for a prescriptive way to do this but