copy and paste this google map to your website or blog!
Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples: WordPress Example, Blogger Example)
NC Garage Legal Finish Requirement | The Building Code Forum The garage is 100% residential- not a business The first floor has lights outlets, the second floor only has a preexisting light fixture (exterior light) from the original house and no added wiring
Equipment Bollard in a Residential Garage - The Building Code Forum Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab We also have two alternates that are wheel stops and pipes bolted to the floor for retrofits 99% of the time we see the schedule 40 pipe embedded in the concrete
fire separation in garages - The Building Code Forum When constructing split entry's, we alway's framed around the steel I-beam and post in the garage, installed gyp and taped the seams Same on the fur-down (duct covering)and ceiling gyp, just tape unless spray texure was being installed, alway's thought that was the code are we requiring something different now?
Minimum Floor Slope for Drainage - The Building Code Forum Irc The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope It is usually 1 8” to 1 4” per foot Here is the citation from the International Residential Code (IRC): R309 4: "The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle
Habitable Space Exiting into a Garage | The Building Code Forum The habitable space only accessed through the garage is a private hair salon, I believe this would be considered habitable space? The other rooms only accessed through the garage are a laundry room, a toilet room and a storage room, all considered non-habitable
2024 Portal Frames | The Building Code Forum In the picture provided, I would say that is still a single portal frame opening I think the intent was to prevent two portal frames immediately adjacent to each other using a common header Example would be at the garage, where for example, multiple garage door openings are on the same wall plane and configured to use a common header over 2+ portal frames - that would be prohibited
Commercial Repair Garages - The Building Code Forum I have plans for a "new" auto dealership with 2 separate bldgs One bldg is the Sales Showroom bldg and the other is the repair shop garage What occupant load would I use for the Shop Areas ( referring to Table 1004 1 1 in the 2006 IBC )? The Gross Area of the Shop is 4,200 sq ft
Private Garages - The Building Code Forum Is a private garage also a parking garage I can see this answer going both ways, with out the aid of definitions Or is a parking garage the same as an open garage only with walls If so, then a parking garage and private garage are the same I have tried to treat them as 3 distinct types of buildings, private garage, parking garage, open garage
Vehicle storage | The Building Code Forum The aggregate quantity of fuel stored in a parking garage will exceed the quantities per a control area for determining Group H, and every car has a fuel tank greater than 5 gallons, so I don’t see how fuel quantity would be a factor—I think the requirements for parking garages takes those specific hazards into consideration