copy and paste this google map to your website or blog!
Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples: WordPress Example, Blogger Example)
16 Garage Door Headers - The Building Code Forum Re: 16' Garage Door Headers conarb said: It's not that simple, almost all garage door headers require portal design, and usually narrow portals integrated with the header, this always requires engineering, listen to your uncle In areas with significant lateral loads from sesmic or wind, yes In areas without such loads, it's not such an issue
Garage Open Air Calculations - The Building Code Forum I am designing a garage, and trying to achieve natural ventilation I think I have achieved the required 20% open, as well as 40% perimeter open as per IBC 2006, but what if your garage is really deep? It seems like if you have a very large garage, if you're 150' from the perimeter, air is not
Slab in unheated garage - The Building Code Forum Now retired and just want to build a garage, so this is a NYS Residential Code question Where does the code - IRC close enough - tell me a slab on grade garage floor in unheated building doesn't have to be protected from frost? Lots of unheated post frame pole barn buildings with an independent slab I them that I'm sure is subject to frost heave
S-1 S-2 Regarding Parking Garage - The Building Code Forum Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy Because the Business Occupancy is a hazard to the S-2 occupancy, a fire barrier wall must be constructed between the two
Commercial Repair Garages - The Building Code Forum I have plans for a "new" auto dealership with 2 separate bldgs One bldg is the Sales Showroom bldg and the other is the repair shop garage What occupant load would I use for the Shop Areas ( referring to Table 1004 1 1 in the 2006 IBC )? The Gross Area of the Shop is 4,200 sq ft
Pex pvc pipes in a garage - The Building Code Forum Are pex pvc water and waste lines allowed to run (exposed) through a garage? I know the code requires ducts to be min 26 gage metal, and other penetrations between garage and house to be protected
Step from garage into House?? | The Building Code Forum I do not see anywhere in the IRC 2015 that requires a step from the garage into the house I saw the opening penetrations R302 5 Garage section R309 Is the step still a requirement and if so is there a minimum dimension?
Garage distance separation from dwelling - Section R309 Re: Garage distance separation from dwelling - Section R309 Uncle Bob, That's how I see it (I just don't believe it) I would not interpret measuring from overhang Any other comments on that? I'll probably stay 5' back The area where the two structure meet is only about 30" of wall length, but there is a window in the garage in that 30"
HVAC in a garage - The Building Code Forum Codes do not permit duct openings in a residential attached garage, for obvious reasons I ran across one yesterday where it appears that the contractor is placing an air handler in a garage under living space My first reaction is -not permitted- however as I thought about it I figured the