Garage pedestrian door size | The Building Code Forum I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door will that size be acceptable since it is not the main egress door?
S-1 S-2 Regarding Parking Garage - The Building Code Forum Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy Because the Business Occupancy is a hazard to the S-2 occupancy, a fire barrier wall must be constructed between the two
2024 Portal Frames | The Building Code Forum In the picture provided, I would say that is still a single portal frame opening I think the intent was to prevent two portal frames immediately adjacent to each other using a common header Example would be at the garage, where for example, multiple garage door openings are on the same wall plane and configured to use a common header over 2+ portal frames - that would be prohibited
Exit Access Stair in Open Parking Garage - Exit Discharge Typically an exit access stair is locate inboard with the exit travel distance continuing beyond the stair to the exit door, but not in this case due to the open parking garage exception
Car Ramp maximum slope - The Building Code Forum Parking garages, other than private garages, shall be classified as public parking garages and shall comply with the provisions of Sections 406 4 2 through 406 4 8 and shall be classified as either an open parking garage or an enclosed parking garage
fire separation in garages - The Building Code Forum When constructing split entry's, we alway's framed around the steel I-beam and post in the garage, installed gyp and taped the seams Same on the fur-down (duct covering)and ceiling gyp, just tape unless spray texure was being installed, alway's thought that was the code are we requiring something different now?
S-1 Motor Vehicle Storage VERSUS S-2 Enclosed Parking Garage Is the following facility an S-1 Storage or S-2 Parking Garage? 7,000 SF metal building - fully enclosed with garage doors and walk doors for access - for parking church vans (all smaller than commercial vehicles) in order to keep them safe when not in use
Exit discharge through open, but covered, parking lot The key is that the open parking garage is well ventilated naturally, and as a result, the products of combustion dissipate rapidly and do not contribute to the spread of fire 1028 3 Exit discharge components