companydirectorylist.com  Global Business Directories and Company Directories
Search Business,Company,Industry :


Country Lists
USA Company Directories
Canada Business Lists
Australia Business Directories
France Company Lists
Italy Company Lists
Spain Company Directories
Switzerland Business Lists
Austria Company Directories
Belgium Business Directories
Hong Kong Company Lists
China Business Lists
Taiwan Company Lists
United Arab Emirates Company Directories


Industry Catalogs
USA Industry Directories












Company Directories & Business Directories

GARAGE R BERNIER

GROSSES-ROCHES-Canada

Company Name:
Corporate Name:
GARAGE R BERNIER
Company Title:  
Company Description:  
Keywords to Search:  
Company Address: 171 132 Rte E,GROSSES-ROCHES,QC,Canada 
ZIP Code:
Postal Code:
G0J1K0 
Telephone Number: 4187334969 
Fax Number:  
Website:
 
Email:
 
USA SIC Code(Standard Industrial Classification Code):
554101 
USA SIC Description:
Service Stations-Gasoline & Oil 
Number of Employees:
1 to 4 
Sales Amount:
$500,000 to $1 million 
Credit History:
Credit Report:
Very Good 
Contact Person:
Raynald Bernier 
Remove my name



copy and paste this google map to your website or blog!

Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples:
WordPress Example, Blogger Example)









Input Form:Deal with this potential dealer,buyer,seller,supplier,manufacturer,exporter,importer

(Any information to deal,buy, sell, quote for products or service)

Your Subject:
Your Comment or Review:
Security Code:



Previous company profile:
MAISON DE GROSSES ROCHES INC
MAGASIN GENERAL H MARQUIS
LE RESTAURANT DU COIN
Next company profile:
ECOLES
ECOLE MGR ROSS
CORPORATION MUNICIPALE DE GROSSES ROCH










Company News:
  • S-1 S-2 Regarding Parking Garage - The Building Code Forum
    Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy Because the Business Occupancy is a hazard to the S-2 occupancy, a fire barrier wall must be constructed between the two
  • Path of egress not thru garage needed for non-living space above . . .
    Just "garage" gets a little messy To me it's a place to park cars and store stuff but I look at some and it's got more space and stuff to totally repair and maintain cars with lifts and all, along with man-cave accoutrements like wet bars and pool tables, etc Just saw one with all that and a half court basketball setup
  • Minimum Clear Height for Parking Garage - The Building Code Forum
    Does IBC specify a minimum clear height is for parking garages? If so, in what section is this found?
  • Garage pedestrian door size | The Building Code Forum
    I have a single car garage with a sectional overhead door, I have space on one stucco wall for a 24 x 75 pedestrian door will that size be acceptable since it is not the main egress door?
  • Garage Open Air Calculations - The Building Code Forum
    I am designing a garage, and trying to achieve natural ventilation I think I have achieved the required 20% open, as well as 40% perimeter open as per IBC 2006, but what if your garage is really deep? It seems like if you have a very large garage, if you're 150' from the perimeter, air is not
  • Egress Door From Garage | The Building Code Forum
    My attached garage has a man door, and my detached garage has a man door On the other hand, under the IBC an overhead garage door is allowed to be used as a required exit door for occupant loads of 10 or fewer (or maybe it's under 10 -- I don't remember) So if the IBC allows a garage door as an exit door, should the IRC be different?
  • Group U private garage building - The Building Code Forum
    Each private garage shall be not greater than 1,000 square feet (93 m2) in area Multiple private garages are permitted in a building where each private garage is separated from the other private garages by 1-hour fire barriers in accordance with Section 707, or 1-hour horizontal assemblies in accordance with Section 711, or both
  • When is a portal frame not needed for a garage door?
    Typically when I draw a garage I just default to the portal frame since they're usually narrow in my area; not much meat on either side of the door I have one coming up that is, for once, not It's a 30x30, 11' ceilings, with a 14' door centered on the gable end I'm having a hard time pointing
  • What is a garage? | The Building Code Forum
    My local code enforcement official here in Maine said that I am allowed to build a structure if it is a one-story garage The thing is, I can't find a definition of what a garage is either in the local code, state law, or the IRC (2015 is applicable for my town) For the sake of avoiding asking
  • Equipment Bollard in a Residential Garage - The Building Code Forum
    Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab We also have two alternates that are wheel stops and pipes bolted to the floor for retrofits 99% of the time we see the schedule 40 pipe embedded in the concrete




Business Directories,Company Directories
Business Directories,Company Directories copyright ©2005-2012 
disclaimer