Minimum Floor Slope for Drainage - The Building Code Forum Irc The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope It is usually 1 8” to 1 4” per foot Here is the citation from the International Residential Code (IRC): R309 4: "The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle
Vehicle storage | The Building Code Forum The aggregate quantity of fuel stored in a parking garage will exceed the quantities per a control area for determining Group H, and every car has a fuel tank greater than 5 gallons, so I don’t see how fuel quantity would be a factor—I think the requirements for parking garages takes those specific hazards into consideration
2024 Portal Frames | The Building Code Forum In the picture provided, I would say that is still a single portal frame opening I think the intent was to prevent two portal frames immediately adjacent to each other using a common header Example would be at the garage, where for example, multiple garage door openings are on the same wall plane and configured to use a common header over 2+ portal frames - that would be prohibited
Equipment Bollard in a Residential Garage - The Building Code Forum Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab We also have two alternates that are wheel stops and pipes bolted to the floor for retrofits 99% of the time we see the schedule 40 pipe embedded in the concrete
Vehicle Repair Facility - Use Group Occupancy? - The Building Code Forum 5248 s f MOTOR VEHICLE REPAIR MAINTENANCE GARAGE a MAINTENANCE BAY: 2569 S F b STORAGE ROOM: 852 S F (INCIDENTAL TO MAINTENANCE BAYS?) c EMPLOYEE ACCOMODATIONS (EMPLOYEE BREAK ROOM, TOILET SHOWER LOCKER ROOMS): 1827 sf (BREAK ROOM = 721 sf) 1 APPLICABLE BUILDING CODE: 2011 OHIO BUILDING CODE 2 PRIMARY OCCUPANCY: S-1 3 CONSTRUCTION TYPE
Repair Garage Ventilation - The Building Code Forum What section in the 2009 IMC allows for CO detection to be the sole method to activate the required ventilation system in a 12,000 sf repair garage? Does 404 1 apply? This is not a parking garage, it is a repair garage Is the system only required to run when CO detectors are activated? What
Vehicle Repair and Sand Oil Separators - The Building Code Forum If the floor of the garage slopes to the entry garage door public works will require a trench across the garage entry and an oil sand separator My owner uses an off-site fluid changing service, and has written a note to that effect, Garages are always going to have chemical spills and droppings on the floor
Commercial Repair Garages - The Building Code Forum I have plans for a "new" auto dealership with 2 separate bldgs One bldg is the Sales Showroom bldg and the other is the repair shop garage What occupant load would I use for the Shop Areas ( referring to Table 1004 1 1 in the 2006 IBC )? The Gross Area of the Shop is 4,200 sq ft
Garage Floor Drain - The Building Code Forum Needing some info on garage floor drain Have read codes that garage floor must slope out or to a drain Have new residential construction with attached garage The builder installed what he identifies as floor drain I drained the livewell from my boat in garage floor Floor is completely
Residential service pit - The Building Code Forum How does a hole in the garage floor comply with this::: 406 3 3 Garage Floor Surfaces Garage floor surfaces shall be of approved noncombustible material The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle entry doorway Click to expand