S-1 S-2 Regarding Parking Garage - The Building Code Forum Because this garage is over 1,000 SF it falls outside the scope of a "private garage" and is, for code purposes, a "public garage" Section 311 3 Classifies "Parking garages, open or enclosed" as a group S-2 Occupancy Because the Business Occupancy is a hazard to the S-2 occupancy, a fire barrier wall must be constructed between the two
Minimum Floor Slope for Drainage - The Building Code Forum Irc The building code requires that a garage floor be sloped towards the door, but does not specify a minimum slope It is usually 1 8” to 1 4” per foot Here is the citation from the International Residential Code (IRC): R309 4: "The area of floor used for parking of automobiles or other vehicles shall be sloped to facilitate the movement of liquids to a drain or toward the main vehicle
Step from garage into House?? | The Building Code Forum I do not see anywhere in the IRC 2015 that requires a step from the garage into the house I saw the opening penetrations R302 5 Garage section R309 Is the step still a requirement and if so is there a minimum dimension?
Garage distance separation from dwelling - Section R309 Re: Garage distance separation from dwelling - Section R309 Uncle Bob, That's how I see it (I just don't believe it) I would not interpret measuring from overhang Any other comments on that? I'll probably stay 5' back The area where the two structure meet is only about 30" of wall length, but there is a window in the garage in that 30"
HVAC in a garage - The Building Code Forum Codes do not permit duct openings in a residential attached garage, for obvious reasons I ran across one yesterday where it appears that the contractor is placing an air handler in a garage under living space My first reaction is -not permitted- however as I thought about it I figured the
Garage Open Air Calculations - The Building Code Forum I am designing a garage, and trying to achieve natural ventilation I think I have achieved the required 20% open, as well as 40% perimeter open as per IBC 2006, but what if your garage is really deep? It seems like if you have a very large garage, if you're 150' from the perimeter, air is not
Pex pvc pipes in a garage - The Building Code Forum Are pex pvc water and waste lines allowed to run (exposed) through a garage? I know the code requires ducts to be min 26 gage metal, and other penetrations between garage and house to be protected
Equipment Bollard in a Residential Garage - The Building Code Forum Re: Equipment Bollard in a Residential Garage We have a minimum 36 inch high 2" schedule 40 iron pipe embedded in the garage slab We also have two alternates that are wheel stops and pipes bolted to the floor for retrofits 99% of the time we see the schedule 40 pipe embedded in the concrete
Path of egress not thru garage needed for non-living space above . . . Just "garage" gets a little messy To me it's a place to park cars and store stuff but I look at some and it's got more space and stuff to totally repair and maintain cars with lifts and all, along with man-cave accoutrements like wet bars and pool tables, etc Just saw one with all that and a half court basketball setup
Slab in unheated garage - The Building Code Forum Now retired and just want to build a garage, so this is a NYS Residential Code question Where does the code - IRC close enough - tell me a slab on grade garage floor in unheated building doesn't have to be protected from frost? Lots of unheated post frame pole barn buildings with an independent slab I them that I'm sure is subject to frost heave