TRAP AND TRAP ARM SIZES, LENGTH LIMITATIONS AND FIXTURE DRAINAGE UNITS Determine the drainage and vent pipe sizes based on the total number of drainage units for each section of pipe See exceptions Drainage pipes for individual fixtures must be at least the pipe size of the trap trap arm per table below
Cal. Code Regs. Tit. 17, § 13603 - Interior Requirements Each drainboard shall be at least the size of one of the sink compartments If multi-use eating and drinking utensils are used, the sink shall have three compartments; each compartment with a minimum size of 12" x 12" x 10 "
CHAPTER 29 PLUMBING SYSTEMS - 2022 CALIFORNIA BUILDING CODE, TITLE 24 . . . In covered and open mall buildings, the required public and employee toilet facilities shall be located not more than one story above or below the space required to be provided with toilet facilities, and the path of travel to such facilities shall not exceed a distance of 300 feet (91 m)
Chapter 29 Plumbing Systems: California Building Code 2013 (Vol 1 2 . . . The minimum number of required drinking fountains shall comply with Table 2902 1 and Chapter 11 Drinking fountains are not required for an occupant load of 15 or fewer For business and mercantile occupancies with an occupant load of 15 or fewer, service sinks shall not be required
Public Restroom Laws in California: Key Regulations and Requirements Restroom stalls must have a minimum door width of 32 inches, and grab bars must be positioned between 33 and 36 inches above the floor Sinks, mirrors, and dispensers must be within reach of individuals using wheelchairs, with soap dispensers no higher than 40 inches from the floor
Chapter 6: Lavatories and Sinks - United States Access Board Kitchen sinks that are adjustable to 29″ minimum and 36″ maximum height are allowed if rough-in plumbing permits connections of supply and drainage pipes for sinks mounted at 29″ high (§606 3, Ex 2)
11B-606 Lavatories and sinks - Corada Water supply and drain pipes under lavatories and sinks shall be insulated or otherwise configured to protect against contact There shall be no sharp or abrasive surfaces under lavatories and sinks
California Public Restrooms Laws - 2024 California Health and Safety . . . California may have more current or accurate information We make no warranties or guarantees about the accuracy, completeness, or adequacy of the information contained on this site or the information linked to on the state site Please check official sources
2016 California Plumbing Code - Loris Web A floor drain shall be provided adjacent to the fixture, and the fixture shall be connected on the sewer side of the floor drain trap, provided that no other drainage line is connected between the floor drain waste connection and the fixture drain