companydirectorylist.com  Global Business Directories and Company Directories
Search Business,Company,Industry :


Country Lists
USA Company Directories
Canada Business Lists
Australia Business Directories
France Company Lists
Italy Company Lists
Spain Company Directories
Switzerland Business Lists
Austria Company Directories
Belgium Business Directories
Hong Kong Company Lists
China Business Lists
Taiwan Company Lists
United Arab Emirates Company Directories


Industry Catalogs
USA Industry Directories












Company Directories & Business Directories

DYNATECH COLLISION INC

OAKVILLE-Canada

Company Name:
Corporate Name:
DYNATECH COLLISION INC
Company Title:  
Company Description:  
Keywords to Search:  
Company Address: 1108 South Service Rd W,OAKVILLE,ON,Canada 
ZIP Code:
Postal Code:
L6L5T7 
Telephone Number: 9054690800 
Fax Number: 9054690804 
Website:
 
Email:
 
USA SIC Code(Standard Industrial Classification Code):
753812 
USA SIC Description:
Truck-Repairing & Service 
Number of Employees:
5 to 9 
Sales Amount:
$500,000 to $1 million 
Credit History:
Credit Report:
Very Good 
Contact Person:
Bill Bertignoll 
Remove my name



copy and paste this google map to your website or blog!

Press copy button and paste into your blog or website.
(Please switch to 'HTML' mode when posting into your blog. Examples:
WordPress Example, Blogger Example)









Input Form:Deal with this potential dealer,buyer,seller,supplier,manufacturer,exporter,importer

(Any information to deal,buy, sell, quote for products or service)

Your Subject:
Your Comment or Review:
Security Code:



Previous company profile:
E & R FURNISHING & MILLWORK INC
DYSLEXIA CORRECTION ASSOCIATES
DYNEGY CANADA INC
Next company profile:
DYNASI RESTAURANT
DYNAMITE DEALS LIMITED
DYNAMITE DEALS LTD










Company News:
  • Mini split wiring | Information by Electrical Professionals for . . .
    Who is the manufacturer? I just wired a mini-split (Mitsubishi) and it required 16 4awg stranded for the LV control (between head - inside control unit - outside) I used CL3 stranded for wet locations For power, outdoor unit requires 15a 2-pole breaker I ran 14awg stranded for that Each manufacturer has different wiring schemes and I believe the NEC indicates the manufacturer wiring
  • Minisplit Wiring | Information by Electrical Professionals for . . .
    The Type MC or TC that is being ran inside to the indoor unit in these mini-split cables are 240V with a 24V control wire (thus why Type TC-ER-JP can be used now in one - and two family)
  • Mini-split A C install - Mike Holts Forum
    A couple years ago I talked to an HVAC guy about putting a mini-split A C in my bedroom It is the main room I use so I figured it would be cheaper to cool one room than the whole house The guy suggested several ways to run the power One was EMT on the outside of the house either along the
  • (2) mini-splits, (1) breaker? | Information by Electrical Professionals . . .
    I am adding (2) mini-splits to my home, 240v, 15a max OCP per unit I have room for one DP breaker in my QO panel, I am not interested in adding a sub panel at this time I would like to run 10-2 UF, off one 30A DP GFCI(per Mitsubishi) breaker, this circuit would then hit (2) 30a, fusible A C
  • Residential Service Load Calculations using high BTU Mini Split HVAC . . .
    Typical Mini Split units that heat and cool are heatpump systems, meaning they do not generally have any kind of electric resistance AUX heat This means your highest running load is in cooling mode In Heating mode the system is performing " Refrigeration " duty which is notably less than AC load
  • Split A C Systems and Local Disconnect Requirements
    When the indoor unit of a split-system A C unit gets power from the outdoor condensing unit, does the indoor unit require a local disconnect switch if the outdoor unit has a lockable disconnect switch?
  • Load Calc for Mini Split System | Information by Electrical . . .
    Ductless Mini Split System: Mitsubishi R454B - 208V, 1PH - MCA: 12A - MOCP: 20A Looked too deep online and get differing answers on this one For the load, I am doing 208V * 12A = 2496 I thought this was Watts but read that it is Volt-Amps based on the MCA? Went down a rabbit hole and got
  • AC Units tripping GFI protection | Information by Electrical . . .
    Because of this, the NEC is processing a Tentative Interim Amendment on 210 8 (F) in order to delay the implementation for these mini-split systems until January 1, 2023
  • What breaker do I need for a ductless mini split compressor?
    I am getting conflicting info on what I will need for a panel breaker for a ductless mini split I have provided the link to the spec sheet for the compressor The fuse is installed and just need to run wire to panel and install breaker The current AC that will be trashed has dual 20 amp
  • Use 10-3 NM-B vs 10-2 NM-B for outdoor mini-split condenser
    Per NEC is it acceptable to pull 10-3 NM-B when only a 10-2 NM-B cable is needed at this time? I understand that the 10-3 provides the "extra" hot (red) conductor, but what does NEC say about the "spare" wire in the cable that is not needed? Cap the white conductor at both ends of the 10-3