Rack PDU Selector - Let us help choose the right Rack PDU Unique colors, input cord plugs and outlet configurations done simply and delivered to specification With Industry leading reliability, manageability, and security, APC Switched Rack PDU's provide advanced load management plus on off outlet level power cycling and
APC Dual Power PDU - Are they any good? - Spiceworks Community Looking for a 230V 16A PDU with Auto Transfer Switch to provide redundant power options for non-redundant network equipment configurations? Here’s some Tripp Lite options in a similar format to the competitor model you mention
Product Specifications - APC Power APC Basic Rack PDUs provide reliable power distribution via a single input with multiple output receptacles and distributes power from low amperage single phase circuits to higher-power 3-phase solutions APC Rack Automatic Transfer Switches (rack ATS) provide reliable, redundant power to single-corded equipment
Solved: Multiple Power Supplies and Multiple UPS - Schneider Electric . . . We're running a couple of servers, all equipped with dual power supplies We have two UPSes powering all servers One each server, power supply A is connected to UPS A; and power supply B goes to UPS B This creates a redundant power source in case an UPS fails The UPSes are connected to the network and we can monitor them through http
Dual Power Supply Server with one on a UPS one not Depending on the type of UPS you have, the UPS may "reconstruct" the incoming waveform when on commercial power or simply pass the input to the output through an internal switching (relay) arrangement
Solved: Multiple Switched PDUs - Schneider Electric Community We are building a new datacenter and I have multiple APC switched PDU's (two per rack) Each PDU is set on its own circuit breaker I then have the servers (with mulitple power supplies) plugged into both PDU's My question is, how can you control (turning off, turning on, rebooting, etc) the server on mulitple PDU's
Solved: Dual PS = Dual UPS? - Schneider Electric Community you might want to consider a few UPS units to input to the ATS which can automatically switch between sources when there are power issues and essentially give you redundant power for ideal redundancy each ATS input source should be connected to an UPS on a separate circuit but if you only get one UPS for your other circuit, you can input both
Solved: Input Supply Requirements - Schneider Electric Community I'm currently running a Smart-UPS 3000 RM XL to power 5 servers, networking and telecoms equipment Load is reported to be about 50% Watts just now with what is probably average server usage The APC requirement calculator, put it at 2200W required for all the equipment Input is via a C19 to BS1363A power cord