Alteon high availability mechanism - Radware Previously the Alteon high availability mechanism was based on the VRRP protocol and was limited The new mechanism support additional tracking options for failover It also supports two failback modes (the behavior when the Active platform goes offline and then comes online again): always failback to the active primary platform, or on-failure failback (only when the current active platform
Downloading and Upgrading Alteon - Radware Upgrading Alteon The procedure for Alteon upgrading is detailed in the Radware Alteon Installation and Maintenance Guide Download the guide from the Customer Portal Also note that Radware recommends that you read the Release Notes before upgrading
Alteon Standalone with AWS LB - Radware Overview This document details the process of configuring and deploying AWS LB with Alteon platforms as its backend pool This guide demonstrates how to set up the Alteon platforms in multi-IP mode, establish proper communication between necessary components, and deploy AWS LB as the frontend load balancer (LB) The environment presented contains two Alteon platforms in standalone mode and one
Troubleshoot Alteon Syslog Server Log Issue - Radware Troubleshooting a syslog issue on an Alteon load balancer involves a systematic approach Here are the general steps you can follow:Step#1:Verify the Alteon syslog configuration:Verify Syslog Server Details: Ensure that the syslog server IP address, syslog format, syslog protocol port number are correctly configured on the Alteon device Via GUI: Navigate to GUI Menu Configuration -> System
How to Export Alteon Techdata File - Radware To export Alteon Techdata file via Alteon Management From the monitor tab select System-> Maintenance From the Maintenance tab click on the Technical Support Data button Click the Generate button Wait for the message that says “The request has succeeded“ Next, export the file using the Export button
ADC Automation with Ansible - Radware Alteon key fields accept only letters, numbers, underscore “_”, hyphen “-“ and dot “ ” In addition use of “#” in a key would cause Ansible to remove the text after this character from the REST API URL sent to Alteon (according to RFC 398) which will create on Alteon an entry with a different key
Alteon Cache Handling Algorithm - Radware b If Alteon is not configured with such a URL exception rule: a If the headers max-age parameter is present, Alteon does not change the headers max-age header b If the headers max-age parameter is absent, but the headers expires parameter is present, Alteon uses the headers expires value to calculate the headers max-age value c
Alteon HTTP 3 Implementation - Radware Alteon supports HTTP 3 from version 33 0 2 0 and above To configure HTTP 3 gateway: Configure VIRT Create a new HTTPS virtual service (443-tcp) Configure HTTP 2 policy Configure SSL policy and server certificate Create an HTTP Content Modification Rule-list Add an HTTP rule with the following parameters:
Viewing Alteon High Availability State - Radware By default, VRRP is disabled Alteon has extended VRRP to also include virtual servers, allowing for full active-active redundancy over Layer 4 From Web Based Management In the Alteon properties panel: From the CLI For vADC or standalone Type the command info sys general Example:
Alteon SSL: Offload SSL with SNI - Radware The hostname that the client includes in the Client SSL Hello message enables the server to select among the available certificates and present the browser with the certificate containing the correct name SNI in Alteon Alteon supports both SSL offloading with and without SNI, according to the following logic: