- Rheem Tankless Water Heater Error Code 12 - Love Plumbing Remodel
I'm asking this learned group because Rheem doesn't have a "contracting plumber" in Grand Junction and most of the plumbers here are not familiar with tankless units I've done all the diagnostic checks suggested by Rheem and they all check out; voltage to the white and blue molex, flame rod status, etc
- Rheem Tankless Questions - Love Plumbing Remodel
DYI'er here, considering installation of a Rheem Ikonic RTGH-SR11i This is the one with the built in recirculation pump This installation would place the water heater in the basement and the crossover valve on the second floor In reviewing the spec sheet and installation documents I haven't
- Rheem Marathon 85 Gallon Electric - element questions
I have a Rheem Marathon MR85245 85 gallon water heater 240 volt feed on 30 amp breaker with10 gauge wire Under “Element Watts“ on the manufacturer’s placard, it reads “4500” for upper, lower, maximum, but it has OEM Rheem 3800 watt elements (stamped 240V 3800W) which is what I’d expect if there was a 12 gauge feed
- Removal of plastic heat trap from new Rheem water heater for . . .
I just replaced an old traditional GE water heater with a new Rheem water heater (also traditional) I have two gravity recirculating loops that worked great with old water heater They don't work with new heater After some research, I think it's because the new heater has heat trap inserts
- Rheem Flammable Vapor Sensor repeated lockouts
Hello, I have a Rheem Powervent water heater (gas) model 42VP40F (40 gallon) manufactured 05 2007 Starting in the last year, the Flammable Vapor Sensor has started tripping intermittently The gas valve I have is a Robert Shaw with a manual red dial About a year ago we had one occurence and
- Rheem Hot Water Heater Condensation issues - Love Plumbing Remodel
Purchased new home with new Hot Water Heaters, one inside the home and one outside in the garage Noticed water standing in catch pan when the heater stopped heating water on the inside heater Contacted Rheem and because the heater was still under waranty, authorized a new heater and it was
- Rheem 82v52-2 element? - Love Plumbing Remodel
It is a Rheem model # 82V52-2, both elements should be 4500 watts To my amazement, labeled on each element is a part number SG1153L My search for these elements tell me they are 1500 watts I called Rheem, they told me they should be part number SP10552MH or SP10552ML 4500 watt elements Now I'm nervous Why would someone put in 1500 watt units?
- Combi boiler can I keep it simple? - Love Plumbing Remodel
Is this a Rheem Prestige Series? Can you provide the actual specific model number? The photo you took is of the heat exchanger and it is not the manufacture of the boiler "Kiturami Co " is just a manufacture of heat exchangers, this same heat exchanger is used on Noritz CB-199 180 models, Rheem, HTP, Westinghouse, Larrs, and more manufacturers as well so that photo does not really help much
|
|
|