  • Changes in the 2024 International Building Code (IBC)
    The 2024 IBC® contains many important changes such as: Duties and powers of the building official: an overall reformat of Section 104 regulating duties of the building official, the approach for reviewing for code compliance has been significantly updated to reflect the current manner that alternate materials, designs and methods are evaluated
  • Area Calculation Clarification - The Building Code Forum
    I have a somewhat basic (dumb?) question about area calculations - Reading through the 2009 IBC it defines building area as: 502 1AREA, BUILDING The area included within surrounding exterior walls (or exterior walls and fire walls) exclusive of vent shafts and courts Areas of the building
  • Occupancy Classification for Townhouse: R-2 or R-3?
    R-2: "Residential occupancies containing more than two dwelling units" If each townhouse is a seperate structure, than it only contains one dwelling unit That makes it R-3, yes?
  • Fire Separation Distance Between New and Existing Building with Windows
    From the 2021 IBC Commentary: The Commentary says: Fire separation distance is the distance from the exterior wall of the building to one of the three following locations, measured perpendicular to the exterior wall face: an interior lot line [see Commentary Figure 202 (19)]; the centerline of a street or public way [see
  • 1, single user, unisex toilet room in coffee shop, per 2021 IBC
    The IBC Commentary language for exception #5 confirms this There is also the exception under the calculations portion , 2902 1 1, reading "Distribution of the sexes is not required where single-user water closets and bathing room fixtures are provided in accordance with Section 2902 1 2 "
  • 1006. 2. 1 Egress based on occupant load and common path of egress travel . . .
    2021 IBC Section 1006 2 1 requires that two exit or exit access doorways shall be provided to any space if the design occupant load or the common path of egress travel exceeds the values outlined in Table 1006 2 1
  • S-1 occupancy, occupant load | The Building Code Forum
    2015 IBC, table 1004 1 2, what does a s-1 storage occupancy (repair garage with ordinary hazard) fall under for the occupant load factor? im thinking industrial at 200 sf per person
  • Mini-Class: Unlocking Chapter 1 of the 2024 IBC – Scope and . . .
    Chapter 1 of the 2024 International Building Code (IBC) establishes the foundation for how the code is applied, enforced, and interpreted It outlines the scope, purpose, and administrative processes that ensure due process while safeguarding public safety, health, and welfare