- Using EHS6 ASC1 UART without RTS CTS lines connected | Thales IoT . . .
Hi all, I would like to connect an external RS-232 peripheral to the ASC1 UART on the Gemalto Concept board Unfortunately, I cannot access the flow control lines on the external hardware I wish to connect to, and the AT command set document (DocID:EHS6_ATC_V02 000) says that the UART must use hardware flow control and the AT\Q commands simply
- Executing PCKS impl throws CKR_MECHANISM_PARAM_INVALID for CKM_XOR . . .
Gemalto's team shared information that 7 0 1 do suppoort the mechanism, so, we proceeded with Java PCKS implementation using JCProv, and when executing the mechanism 'CKM_XOR_BASE_AND_DATA' it throws an error
- No response from AT command (Gemalto EHS6T-Lan) | Thales IoT Developer . . .
My Gemalto ****m hung after some period of time if no usage I won't have any response from AT command after I access via telnet and port and issue the AT command It just hung there and seems waiting for response
- BGS5 Java Users Guide | Thales IoT Developer Community
Java technology and several peripheral interfaces on the module allow you to easily integrate your application This document explains how to work with the ME, the installation CD and the tools provided on the installation CD
- Receiving SMS URC trouble Firmware version | Thales IoT Developer Community
SLAE is the preinstalled application that can be used to communicate the module with https: **** gemalto io platform It's a special service for remote monitoring of the module's state, firmware or application update etc
- Linux FW update procedure for PH8, PHS8, PVS8 and PXS8 . Glinswup . . .
Linux FW update procedure for PH8, PHS8, PVS8 and PXS8 Glinswup | Thales IoT Developer Community Like 4 0 Alopez October 22, 2014 - 2:11pm, 5859 views Modules
- SMTP and Gmail. . . no longer working? | Thales IoT Developer Community
A while ago I was playing around with the AT command example for sending email as per the EHS6 AT command instruction set datasheet It worked just fine Fast forward a few months and i fired up the exact same board but now smtp and gmail doesn't work On AT^SISO=9 ^SIS: 9,0,1000,"PARA-ERR: cmd must be set" (I always get this as I'm not using files but it doesn't seem to matter) ^SIS
- BGS2T (BGS2-W) CSD call to roaming SIM in other jusistriction | Thales . . .
I'm trying to make a CSD call from a BGS2T terminal (REVISION 01 301) (2G) to another terminal which has either a roaming SIM in the same jurisdiction or a local SIM in a different jurisdiction I know that CSD's days are numbered but we have legacy systems or some clients that insist on it still I very quickly receive only 'NO CARRIER' I can call other CSD SIMs without issue
|
|
|