  • NEC 2023 gfci requirements? | Information by Electrical Professionals . . .
    If so how would that solve a GFCI tripping issue? A DF breaker is a GFCI with AFCI protection If you are installing a GFCI receptacle maybe the brand of GFCI you are using is not liking something about the machine? It really doesn't make sense to install a GFCI receptacle since an AFCI breaker plus a GFCI receptacle costs more than a DF breaker
  • RCD Breaker Vs GFCI Breaker | Information by Electrical Professionals . . .
    GFCI is the term normally used in the USA As others post, the standard trip setting is about 5ma which gives good protection against electric shock GFCIs are available either to fit in a panel, or built in to a recepticle socket outlet The ones built into an outlet, also protect any downsteam outlets on the same circuit, if correctly wired
  • 5mA vs. 30mA sensitivity GFCI breaker | Information by Electrical . . .
    GFCI breaker is causing nuisance tripping for a food warming equipment in a small commercial project, where customers can use this food warming equipment, but the the whole business is not about food, of course To solve this problem, motor rated GFCI was selected The 5mA sensitivity GFCI (which is good for personnel protection) was still causing nuisance tripping Would it be acceptable by
  • Range Tripping GFCI (210. 8, 555. 53) | Information by Electrical . . .
    I assume this has been discussed already in this forum but I wasn't able to find a recent thread NEC 2023 210 8(A)(6) requires all 125-250V single phase receptacles in a kitchen to be GFCI protected We recently rewired a kitchen including a 50A GFCI circuit to a Miele induction range They
  • GFCI Breakers - Needed for EV? | Information by Electrical . . .
    The GFCI won't stop unqualified persons from lifting that noodle, or causing other typical hazards Since GFCI's only monitor Line-to-EGC, if raceways are subject to damage, or open outlets can be reached by toddlers, not behind a lockable outdoor enclosure, occupants can still get electrocuted from any Line-to-Line, or Line-to-Neutral contact
  • Sauna GFCI? | Information by Electrical Professionals for Electrical . . .
    Hi all, I'm installing a circuit that goes out to a separate structure for a sauna This sauna heater is the type you have rocks on and pour water over according to the customer I would think that would need GFCI protection buy I didn't see anything in the manual or NEC Has anyone else came
  • EV Charger GFCI Receptacle Requirements | Information by Electrical . . .
    I'm installing a EV charger that requires a NEMA 6-50 receptacle The system is a 120 208 3 Phase 4 -wire system It's a cutler hammer panelboard that utilizes bolt on circuit breakers To my knowledge there is no GFCI circuit breaker to accommodate this panel I'm under the 2017 NEC
  • NEC 2023 Article 210. 8- GFCI Protection for Appliances
    Do Commercial washer machine in a commercial laundromat require GFCI protection per NEC 2023? NEC 2023 Article 210 8 list dryer but not washer Does any one know why that is?